Cleaning cage clipped the bottom corner of the kitchen corridor fire door back in September, and the facing has peeled a little further every week since. 🧹
1
14
We'd make that call door by door and write the reason down either way, so it's on file when an auditor or assessor asks why.
1
2
Strips, smoke seals or both? The door's test evidence sets the strips and its position sets the smoke seals, so FD30S stair doors need both. protestesltd.co.uk/fire-door…
32
New hardware on an old fire door is worth a second look 🔩 - handles bolted through in new spots - hinges from a general hardware store - empty screw holes It's all part of the tested door. 🌐 protestesltd.co.uk?utm_sourc… 📞 01604 696113
8
Unhooking the closer arm leaves the closer bolted to the door looking normal, while the door stays wherever it was last left. 🚪 On a corridor that's busy all day, the closer is what gets that door shut after every person through it. 🔧
9
Back in October the stair door by the loading bay started sticking after a wet week, so someone took a plane to the latch edge and it shut nicely again. 🪵
1
2
223
The better route is to find the moisture, let the door settle and then reassess it. A badly swollen or delaminated leaf is usually a replacement, and trimming it rarely saves it.
1
2
Coat hooks screwed into the back of a meeting room fire door are easy to miss. 🧥 Two more: - noticeboards fixed through the leaf - bolts added for privacy Each one changes a tested door. 🌐 protestesltd.co.uk?utm_sourc… 📞 01604 696113
1
19
Cracked glass in a fire door vision panel matters because the glass, beads and glazing seal were all part of what the door was tested with. 🪟 The replacement has to match that evidence too. When did anyone last check yours? 🔍
2
26
A slamming fire door usually needs its closer adjusted in small turns, then testing from every angle so it still latches. protestesltd.co.uk/fire-door…
1
1
2
29
Somebody swapped the lock on the plant room fire door a while back, and the old cut-out is still there under a smear of wood filler and a coat of paint. 🔩
1
24
Small redundant screw holes can often be made good with a method the manufacturer allows. A bigger cut-out needs a proper look, and sometimes it's the reason the leaf has to be replaced.
1