Prof. Bryan Marcia, Emeritus, Dept. Nat. Med. (@Prof_Bryan_) header
Prof. Bryan Marcia, Emeritus, Dept. Nat. Med. (@Prof_Bryan_) profile picture

Holed up in a sleepy Mexican fishing village, quietly building what may become one of the most accurate neurological diagnostic imaging tools known to mankind.

Mexico
Joined March 2025
Photo by Prof. Bryan Marcia, Emeritus, Dept. Nat. Med. (@Prof_Bryan_)Photo by Prof. Bryan Marcia, Emeritus, Dept. Nat. Med. (@Prof_Bryan_)Photo by Prof. Bryan Marcia, Emeritus, Dept. Nat. Med. (@Prof_Bryan_)Photo by Prof. Bryan Marcia, Emeritus, Dept. Nat. Med. (@Prof_Bryan_)Photo by Prof. Bryan Marcia, Emeritus, Dept. Nat. Med. (@Prof_Bryan_)Photo by Prof. Bryan Marcia, Emeritus, Dept. Nat. Med. (@Prof_Bryan_)Photo by Prof. Bryan Marcia, Emeritus, Dept. Nat. Med. (@Prof_Bryan_)
My newest app, 'PupilCheck' is currently offering a Free lifetime License for Testers. This app measures pupil size, position and shape from still photographs. Close-up focus, exposure and sensor noise vary enormously between phones, and we can only find out what happens on yours if you run it and let us know your experience. Android only at this time, iOS later. Check it out at: cnri.edu/pupilcheck/
1
131
My new "Dual-Camera Pupillometer" Prototype.. getting closer but still seems far away.. A few images of my first 3D-printed prototype for a dual-camera NIR pupillometer, a device that measures both pupils at exactly the same moment using invisible infrared light. This approach avoids timing errors and false anisocoria caused by normal pupil fluctuations, while producing high-contrast images without triggering pupil constriction. Instead of relying on a subjective penlight exam or a single-camera pupillometer, the goal is to produce precise, objective numbers for pupil size, reaction speed, and other measurable parameters. The end result: faster and more reliable detection of unequal or sluggish pupils that could signal midbrain or third-nerve injury following sports impacts or accidents (TBI). Meanwhile, over the past year... Software engineering: ✅ Software completed. Hardware engineering: ✅ Hardware completed. Electrical engineering: My current task, the electrical components are now sitting on my desk. Along with a freshly AI-generated 24-page “Electrical Installation” manual, which I assume is either going to help me finish the project or become Exhibit A in an investigation. 😅 And then there is the final boss: Certifications. 😬 Pupillometers, biometric iris scanners, and eye trackers fall into the world of ophthalmic instruments. That means I don't just get to build something that works and say, “Look! The pupils are doing science!” The device has to satisfy standards including IEC 62471 and ISO 15004-2 (and ANSI Z80.36 in the U.S.), which impose much tighter safety limits around cornea, lens, and retinal exposure because the pupil can be large, the eye may be held still, and the exposure is deliberate. Then medical-device regulations enter the chat, including FDA and EU MDR requirements, meaning the safety assessments, testing, quality systems, and supporting documentation all have to be properly evaluated and certified. So I ran some preliminary numbers.. Getting this dual-camera NIR pupillometer through the necessary safety and medical-device certification process could mean roughly $10k–$20k for light-hazard testing and potentially $80k–$250k+ for U.S. + EU medical certification, depending on how much of the QMS and IEC 60601 package needs to be developed from scratch. So, after diving into software engineering, hardware engineering, and now currently learning electrical engineering during this past year, I've arrived closer to the final stage: How to pay for certification and approved IRB clinical study at private hospital for possible FDA approval. If there are any investors, medical-device people, engineers, neurology folks, or generally adventurous humans out there who think this project has potential... I would love to hear from you. I am now discovering that building the thing was only the beginning!! 😅 The "PupilMetrics Research" app is available at Microsoft (windows) or Google Play (android) stores. I have a limited-license, non-Play Store version available for extended research use. If you’re interested in trying it out, send me a message, I’d love to get it into the hands of researchers and hear your feedback. Please note this app is currently not available for iOS iPhones at this time, but more than happy to share the macOS DMG version for side-load upon request. #Neurology, #Neurotrauma, #TBI, #Concussion, #SportsMedicine, #Stroke, #Neuroscience, #Pupillometry, #BrainInjury, #Neurotechnology, #MedTechStartup, #MedicalDeviceStartup
5
248
Pupil testing hasn’t been adopted in pro football because it would make players look weak. Think about it. The culture still rewards guys who “play through it.” The guy who says “I’m good” after a big hit gets celebrated. Now imagine a little device on the sideline says: “Actually… your pupil habituation is messed up and your brain is still recovering.” That device would be the ultimate snitch. It doesn’t care how tough you are. It doesn’t care about your contract year. It just reports what the brainstem is doing. In a league that still sometimes treats concussions like a character flaw instead of a brain injury, objective data is dangerous. It removes the ability to “tough it out” and look heroic. My latest research proposes exactly how to implement this as a practical monitoring platform for football, sideline and serial tracking included. researchgate.net/publication… #Concussion #SportsMedicine #Pupillometry #Football #TBI
1
1
77
Why doesn’t the NFL (or any major league) make objective pupil testing standard in concussion protocols? I have a theory. And it’s not pretty. Pupil testing is fast, cheap, objective, and can’t be faked by a tough guy saying “I’m good, coach.” It would show real neurological changes even when the player passes every other test and wants to get back in the game. Now imagine you’re the league. Every time that little pupil analysis device beeps and shows abnormal habituation or slowed constriction… that’s now documented evidence. Evidence that can be subpoenaed. Evidence that can be used in lawsuits. Evidence that says “this player’s brain was not normal when we let him back on the field.” Right now, most protocols are still heavily based on “how do you feel?” and “can you remember three words?” Subjective. Contested. Easy to argue in court. Objective pupil data? Not so much. So the theory is simple: They’re not avoiding pupil testing because the science is weak. They’re avoiding it because the data would be too strong. Too many documented cases. Too many players who “felt fine” but whose pupils told a different story. It’s the same reason some places still resist baseline testing or advanced imaging. When you have hard numbers, you can no longer pretend the problem is smaller than it is. But until the incentives change, we’ll keep relying on “he says he’s okay.” What do you think? Liability protection or just old habits? #Concussion #SportsMedicine #Pupillometry #Football #TBI
1
54
We have sideline tablets, apps, and protocols for everything… except the one measurement that’s been validated in actual brain injury care for decades? Can anyone tell me why? 🤔 Post-concussion pupil changes include anisocoria (unequal pupils), dilated or constricted pupils and slower reaction to light. Even more telling is abnormal pupil habituation, the pupil fails to adapt normally to repeated light flashes. This reflects disrupted brainstem, autonomic, and cortical networks. The injury doesn’t damage the eye, it disrupts the brain’s control of the pupil. Quantitative pupillometry gives us objective numbers: Resting size Constriction speed Habituation Recovery time Portable. Sideline-friendly. Repeatable. How many more papers and decades of data do we need before someone says, ‘Hey, maybe we should actually use the pupil test we already know works’? #Concussion #SportsMedicine #Pupillometry #Football #TBI
2
69
After 40+ years studying the human pupil and TBI, I’m still shocked: No major pro sports league uses objective pupil testing in concussion protocols. Why? The pupil is a direct, measurable window into brain function, and it changes after concussion. Go figure.. #Concussion #SportsMedicine #Pupillometry #Football #TBI
1
2
171
How PupilMetrics Gets Its Results -The Science Behind the Analysis! PupilMetrics uses a three-stage hybrid analysis pipeline: Stage 1: Classical Computer Vision The app applies pixel-level image processing to the iris photograph to extract: - Pupil-Iris (PI) Ratio - the proportion of pupil diameter to total iris diameter, a key clinical marker. - Ellipseness - how circular or oval the pupil is - Decentralization - how far the pupil center deviates from the iris center - Anisocoria detection - difference in pupil size between left and right eyes - Autonomic Nerve Wreath (ANW) assessment - ratio, form type (lacerated, scalloped, straight), and directional shifts Stage 2 — ONNX Machine Learning Model Simultaneously, a trained neural network (CNRI's cnri_model.onnx, calibrated on 712 Bexel clinical cases) independently estimates the same four iris metrics. The ML model processes a 224×224 crop of the iris region and outputs PI ratio, decentration, ellipseness, and anisocoria values. Stage 3 — Hybrid Confidence Fusion The two independent results are fused using a weighted confidence formula: ┌─────────────────────────┬────────┐ │ Component │ Weight │ ├─────────────────────────┼────────┤ │ Capture quality │ 20% │ ├─────────────────────────┼────────┤ │ Classical CV confidence │ 35% │ ├─────────────────────────┼────────┤ │ ML plausibility │ 20% │ ├─────────────────────────┼────────┤ │ Cross-model agreement │ 25% │ └─────────────────────────┴────────┘ The final hybrid confidence score (0–100%) tells you how reliable the analysis is. Scores above 70% are rated High - meaning both analytical methods agree and the image quality is sufficient for clinical use.
107
Prof. Bryan Marcia, Emeritus, Dept. Nat. Med. retweeted
Natural Compound in Fruit and Vegetables Found To Slash Heart Disease and Diabetes Risk scitechdaily.com/natural-com…
2
3
460