Dr. Diego López (@TraumaRuberINT) header
Dr. Diego López (@TraumaRuberINT) profile picture

Traumatólogo especialista en fracturas, prótesis de cadera y rodilla. Hospital Ruber Internacional

Madrid. España
Joined October 2017
Photo by Dr. Diego López (@TraumaRuberINT)Photo by Dr. Diego López (@TraumaRuberINT)Photo by Dr. Diego López (@TraumaRuberINT)Photo by Dr. Diego López (@TraumaRuberINT)Photo by Dr. Diego López (@TraumaRuberINT)Photo by Dr. Diego López (@TraumaRuberINT)Photo by Dr. Diego López (@TraumaRuberINT)Photo by Dr. Diego López (@TraumaRuberINT)Photo by Dr. Diego López (@TraumaRuberINT)Photo by Dr. Diego López (@TraumaRuberINT)
How do you remove this cortical fragments if you don’t use postero-lateral ankle approach? @traumaticum
6
1
3
4,238
Naaaa na nana na naaaa…hey jude. LEGEND
209
77 yo, pluripathological patient, combo nail and plate. Suprapatellar nail
2
1
299
Percutaneous acetabular fixation
2
5
38
4,674
Female, 82yo, tibial plateau tipe (1+4) schtzk fracture, bilateral conminuted humeral fractures and C1-C2 fracture.@KneeUnit @traumaticum @EdinburghKnee
1
1
1,089
un caso de acetábulo muy bien resuelto linkedin.com/posts/guillaume…
201
Ante una fractura….🤔📐📏
2
Dr. Diego López retweeted
More caudally, the axial postop CT image shows the caudal PW and transverse details
1
12
Dr. Diego López retweeted
The mid level postop axial CT image also shows the details
1
1
11
Dr. Diego López retweeted
The postop axial CT at the dome level shows the detailed results of the reduction and fixation and bone grafting
2
1
10
Dr. Diego López retweeted
The IO view shows that the caudal screws (and in this case the cranial ones too) are not in the joint
1
2
6
Dr. Diego López retweeted
The plates should be well contoured to have uniform contact with the cortical bone surfaces - the OO view shows the cranial screws and the long AC screw to be not in the joint
1
2
8
Dr. Diego López retweeted
Then the contoured malleable plates are positioned to support the PW fragments and further secure the Transverse as well - you can see that several plate screws are interfragmentary screws through the cranial and caudal PW fragments
1
2
9
Dr. Diego López retweeted
Using biplanar fluoro, the AC part of the TR fracture reduction is secured with a percutaneously inserted 4.5mm cortical lag screw
1
1
4
Dr. Diego López retweeted
Once the fracture surfaces have been cleaned, the transverse fracture is reduced and clamped, the impaction articular pieces reduced and grafted, and then the PW fragments are reduced and wired
2
1
4
Dr. Diego López retweeted
The intraop obturator oblique shows the minimal transverse location and displacement, plus the displaced PW cranial and caudal fragments
1
1
3