Pinned Tweet
🧵 Write up of Laianzhi KN95 (*LAZ/KN99) T99+ HYX02
Disclaimers: Not a review but personal observations after some exploration. I do not have access to a PortaCount. Not affiliated with Laianzhi.
Photos are from my phone camera.
1/14
Things I'd like to see, any given day.
Big pile of stuff getting shipped / delivered today. Thanks to all the folks who've waited patiently while we get these ready. Feel free to bug us for an update as we work our way through the list.
#airpurifier #covidisairborne #indoorairquality
Steve T retweeted
I have had extreme compassion & empathy for everyone for the last 6 years, but the last week has changed me, & now I just feel rage. The refusal to protect sick kids, coupled with intense denial & pretending, is unforgivable. Everyone is a monster. This is humanity’s final form. We won’t survive this.
Steve T retweeted
Congratulations @longcovidriseup for presenting the Long Covid Declaration at the Demystifying LC Conference in Nice 🙏👏
#LongCovid
Steve T retweeted
Advice for existing Zimi users trying Ziga for the first time:
1. If you have previously used a specific size of Zimi mask, you can continue using the same size for Ziga. Alternatively, you may wish to try other sizes to see which one fits you best.
2. You can start by purchasing individual masks to test the fit; if you require additional frames, you may opt for a boxed set.
3. Zimi masks consist of a filter element and a frame, whereas Ziga masks consist of a filter element, elastic straps, and a frame. Please remember to purchase the elastic straps! Both the elastic straps and the frames are reusable and washable; the number of times they can be reused depends on your individual usage habits.
4. Model correspondence: 9541 = B95-M, 8210 = B95-L, 9233 = A100-M, and ZM100 = A100-L. Products with an "F" suffix consist solely of the filter element and do not include elastic straps (these must be purchased separately and attached by the user). For example, A100F refers to the filter element for the A100 model; to use it, you will need a corresponding frame and two elastic straps.
5. Filter elements are no longer categorized by how they are worn (headloop or earloop); instead, they are distinguished only by color (white or black) and whether or not they include an exhalation valve.
Steve T retweeted
We made a video to show the strong vacuum from the intake side of AirFanta 5Pro. Although it has four sides intake, but still, the vacuum is strong enough to hold 15 pieces of tissues.
Steve T retweeted
A family portrait: here are 18 pathogens that can be transmitted through the air we breathe—in some cases, almost exclusively so. The diseases they cause are known as "airborne" diseases. Among them: measles, COVID-19, influenza, tuberculosis...
(new version of our infographic)
Steve T retweeted
In an attempt to continue to be pathogen free and not end up with a nosocomial infection from a hospital visit, I had to write another letter.
The first letter was successful and everyone on the colonoscopy team wore N95s and were gracious about it.
1/
Steve T retweeted
Thanks to this mask manufacturing plant in Shanghai, China, for helping me test masks this Monday. I won’t be pursuing EN149 or NIOSH certifications in the near term; however, if you are looking for masks with NIOSH certification, you might want to consider those produced by this manufacturer (YICHITA).
Zimi users please read for better understanding. Thank you for explaining, @ghhughes . It's very important that there is clarity.
This should re-assure Zimi users that the batch of filter media suspected of being subpar is still standards compliant and protective.
But the issue wasn't a phantom. It is real. There was an actual, if small, reduction in filtration from the usual performance of that filter media.
"these batches demonstrated filtration efficiencies of 97.44%, 98.31%, 98.55%, and 98.08%, respectively....these results show a slight decrease; nevertheless, they remain fully compliant with the KN95 standard."
Thanks to @zhouliang_mask for following up on this even though he left Zimi many months ago to start Ziga mask. And thanks to the community fit testers who noticed the deviation in PortaCount results and wanted to make sure Zimi's were still providing the protection people count on them for.
It's interesting and useful that PortaCount fit testing was sensitive enough to detect the slight decrease in filtration efficiency, but also a reminder that PortaCount testing in N99 mode won't necessarily give an OSHA passing fit factor of 100 even for NIOSH compliant N95s or GB2626-2019 compliant KN95 masks.
N95s and KN95s are allowed to have up to 5% filter penetration at 85 liters per minute of airflow. Even with a perfect face seal, 5% filter penetration would show as a "failing" fit test score in N99 mode. N99 mode can't tell the difference between allowed filter penetration and a face seal leak.
In practice, you shouldn't get full 5% filter penetration in an N99 mode fit test of an N95 fit test since, A) most N95 filter media has less than 5% filter penetration and B) you don't breathe at 85 liters per minute of airflow.
But even 1.5% filter penetration would be a failing fit test in N99 mode since only a 1% face seal leak or less is allwed. This is why N95 mode was developed for fit testing of N95s, to detect just face seal leakage. And why the Zimis could test lower than usual in N99 mode PortaCount testing, but still be compliant with the KN95 filtration standard.
Community fit testers generally use N99 mode on N95s for two reasons:
• Affordable surplus PortaCounts only have N99 mode, so we use what is available and keep the limitations of N99 mode in mind when evaluating fit test scores for series 95 masks.
•Because we want to test overall protection - how many particles get into a mask - not just meet minimum OSHA face seal leak requrements.
Some people would like fewer particles in their masks, fewer than allowed under the N95 standard, irrespective of how they get into the mask. N99 mode fit testing allows us to rate respiratory protection on a continuum from least protective to most protective.
N95 mode is a great tool for N95/KN95 fit testing and community fit testers do use it when appropriate and they have the equipment available to do it.
In the US, workplace fit testers pretty much always use N95 mode for N95s because their job is to test for face seal leaks, and only face seal leaks. OSHA requires all masks to be NIOSH approved, which thus are assumed to filter well. And N95 mode is designed to test just for face seal leaks and not filter penetration.
What Fe. said.
I’ll choose engineering excellence over vibes and rage bait any day of the year.
#GimmeZiga
Steve T retweeted
Today, I visited a NIOSH-certified mask manufacturing facility to further investigate the correlation between the N99 "fit scores" I personally measured and the actual filtration efficiency of the masks. Using a TSI 8130 tester, the facility’s technicians evaluated four batches of Zimi masks—the same ones that had yielded poor fit scores (ranging from 31 to 66) during my previous testing. When subjected to a salt aerosol loading test (based on the GB2626-2019 KN95 standard), these batches demonstrated filtration efficiencies of 97.44%, 98.31%, 98.55%, and 98.08%, respectively. As an engineer, while I typically state that my KN95 masks offer 98% filtration efficiency—a figure that often exceeds 99% in actual use—these results show a slight decrease; nevertheless, they remain fully compliant with the KN95 standard. This matter is now settled, and any further steps will be handled by Zimi. I have been under immense pressure recently and have faced criticism from various quarters. To those who have attacked me: I hope you never purchase Ziga masks. To those who choose Ziga masks, I guarantee that you will have an optimal wearing experience.
Steve T retweeted
We have received several reports about the 5Pro: the filter came loose after the unit was transported or moved.
This only occurs with the filter without carbon. The filter with carbon is less compressible due to its honeycomb structure, so it fits more tightly at the same dimensions.
The cause is a tolerance issue in the filter dimensions—some filters are about 0.1 mm smaller than the standard size, resulting in an insufficiently tight fit with the plastic frame. If the filter is not fully pressed into the plastic frame, and vibration during transport is added, there is a small chance it could fall out of the plastic frame.
Solutions:
1. During installation, be sure to press the filter fully into the plastic frame until it cannot go any further.
2. Insert the handle printed with "AirFanta" between the filter and the plastic frame to increase tightness.
3. After transporting the unit, open the top cover and visually check that the filter is properly seated.
For future filter production, dimensions will be controlled to the positive tolerance, ensuring the fit is at most on the tight side.
Steve T retweeted
The past six years is the Covid pandemic, where a SARS virus known to cause diabetes, has been left to spread unchecked
The number of women under 40 developing Type 2 diabetes has risen by almost 50% over the past 6 years, with experts saying the surge could be down to a lack of follow-up care for those who develop the condition during pregnancy.
Gestational Diabetes happens when women are unable to produce enough insulin while pregnant.
Plenty of Normies are projecting. And they won't stop projecting unless they hit an eureka moment. And that Eureka moment in year 8 and onwards, will not be f*cking pleasant.
Steve T retweeted
People with hypermobile Ehlers-Danlos syndrome were nearly 3x more likely to develop Long COVID, based on analysis of nearly 20 million Americans EMR data. The data also revealed that hEDS occurs in 1 in 800 people, making it significantly more common than older estimates.
🔍👇🔗
Steve T retweeted
I have just been in touch with Zimi and will be assisting them with further testing. Although I have left Zimi, I do not want those who trust me to feel uneasy. Please refer to the Zimi website or official announcements from Zimi for information regarding how the situation is being handled. I do not follow the "Zimiair" account—in fact, I have blocked it on Twitter—because the content they post is, quite frankly, embarrassing.
Steve T retweeted
👆This Chinese engineer covers your respiratory health — with the best-value air purifier that's detachable and portable.
This Chinese engineer covers your respiratory health — with the KN95 respirator that's supremely comfortable to wear. @zhouliang_mask
This Chinese engineer covers your respiratory health — with far-UVC. @NukitToBeSure
People really need to stop hating on the chinese.
Every time the world's giving me lemons, some chinese engineer's there to help made me lemonade.
Iran war hitting oil? China's releasing the reserves. Gas too expensive? See me in that BYD.
Open AI fucking me on tokens? Got my brother DeepSeek. Claude hitting safety guardrails? We're revisiting abliterated Qwen.
Tech people complaining about token prices, normal people complaining about gas.
The chinese got you covered with a cost-of-living intervention just when you are in a pickle.