Joined November 2018
🫀Finerenone vs spironolactone in heart failure with mildly reduced or preserved ejection fraction: a real-world study. see@ ow.ly/LcYk5100u04 @EJHFEiC @AmrAbdin10 @GiuseppeGalati_ @HanCardiomd @EJHFEiC @JanBiegus @ppponikowski #HFA_ESC @hvanspall @FudimMarat @gcfmd @MarcoMetra @GianluSava #ESCHeartFailure
3
137
8
398
34,089
Gian Manuel Jmz Rdz retweeted
👉PCSK9 gene editing: One shot. Lifelong LDL-C lowering? ☝️ A new review explores the promise and challenges of CRISPR-based PCSK9 gene editing. 1️⃣ One-time treatment: A single infusion could provide lifelong reductions in PCSK9 expression and LDL-C. 2️⃣ Early human evidence: VERVE-102 and YOLT-101 have demonstrated substantial LDL-C reductions, reaching approximately 50% at selected doses. 3️⃣ The major advantage: Decades of LDL-C lowering without repeated dosing. A potentially transformative approach to cumulative cholesterol exposure. 4️⃣ Safety considerations: Early clinical results are encouraging. Larger studies and longer follow-up are needed to establish long-term safety and durability. ☝️ The next frontier: Can sustained LDL-C reduction from a single intervention translate into greater lifetime cardiovascular protection? 🔗🔓 doi.org/10.1007/s11883-026-0… @amitvkhera @society_eas
2
19
1
45
2,560
AngioVAC for left-sided intracardiac masses shows good effectiveness. Careful case selection, timely workup, and optimal embolic protection strategy are necessary. @PedroMDMSc @ShimamuraMD @DrMarvinEng @AhmadJabri8 @g_giustinoMD @vonBardelebenRS @engelpedro @Tiberio_Frisoli
Transcatheter vacuum-assisted extraction of left heart and aortic arch masses showed promising early effectiveness in this multicentre registry. The observed rate of adverse events suggests the need for careful patient selection and improved procedural safety. eurointervention.pcronline.c… #InterventionalCardiology #StructuralHeart #TranscatheterInterventions @fangjonathanx @PedroMDMSc @BillONeillMD @MichaelChiangCS @ArturoGiacaman @vonBardelebenRS
1
4
16
1,102
Gian Manuel Jmz Rdz retweeted
Tomizawa et al. found that super-resolution deep learning reconstruction (SR-DLR) improved CT-FFR performance, increasing AUC from 0.72 to 0.85 and diagnostic accuracy from 74% to 85% vs. normal-resolution DLR (NR-DLR). doi.org/10.1016/j.jcct.2026.…
4
6
365
Gian Manuel Jmz Rdz retweeted
✂ Biopsy forceps... for pulmonary #thrombus removal? When standard balloon angioplasty couldn't break the cycle of recurrent #CTO reocclusion, Nagayoshi et al. went off-label to mechanically remove an organized fibrotic "cap". Read the case: asiaintervention.org/article…
1
10
13
2,385
Preemptive left stellate ganglion block was associated with a reduced incidence of postoperative atrial fibrillation within five postoperative days in patients undergoing CABG with cardiopulmonary bypass. Read more in #JACCCEP 👉 bit.ly/4j7PmXf #CardioX
2
14
27
4,347
Gian Manuel Jmz Rdz retweeted
Missed a CardioTube session? Don't worry, we got you covered ❤️ catch up on all the latest #cardiology content! CRTTV.org has all the info 🫀 #CRTonline #interventionalcardiology #healthcare #technology #AI #nurses #doctors #tech #cathlab #medicine
1
1
188
Gian Manuel Jmz Rdz retweeted
When Is a Coronary Artery “Small”? RCTs suggest DCBs are non-inferior to DES in small vessels. But where’s the cutoff? The magic number for long-term stent patency is an MSA of 5.5 mm², corresponding to a vessel diameter of 2.6 mm. See the sizing chart below. The question of the day: Is a ref. vessel dia. (RVD) of 2.75 mm the tipping point for choosing DES over DCB? 🤔
If 3mm DCB fully yielded without recoil in this young man without heavy calcium then that’s an MLA of 7mm2. It’s adequate.
2
32
1
99
7,906
Gian Manuel Jmz Rdz retweeted
Thoughts on How to Achieve the Optimal MSA with PCI The suggested cut-off of 2.75 mm in my previous post is to guide the choice between DCBs and DES. It is NOT a suggested target MSA. The goal is to achieve at least 90% of the ref. MSA, as proposed by @SripalBangalore et al. Additional thoughts on how to do this are in my reply.
Interesting way of looking. There are obvious limitations of absolute MSA threshold. A MSA of 5.5 in a proximal artery with ref dia of 4.0 mm, is only 44% area expansion but clearly too big for distal small vessels. In an editorial, we proposed (for LM) the below relative MSA.
5
29
4,023
Gian Manuel Jmz Rdz retweeted
Puntuación SYNTAX para la evaluación de la carga y complejidad de la enfermedad arterial coronaria: pasado, presente y futuro #REC #Aheadofprint @he1thj revespcardiol.org/es-puntuac…
11
41
1,579
Gian Manuel Jmz Rdz retweeted
⚙️ IMPELLA SMARTASSIST: HOW TO ADJUST THE LV SIGNAL? SmartAssist system provides valuable information about LV. pressure. 👉Learn why, when and how to do it: youtu.be/i9iz-6QJNMk. #Impella
2
5
520
Not all apoB-containing particles tell the same story. 🔹 Non–Lp(a) apoB → greater coronary plaque burden 🔹 Greater relative Lp(a) contribution → more vulnerable plaque features New in #EJPC: Balance between apoB and Lp(a) may add another layer to cardiovascular risk assessment and personalized prevention. ow.ly/uL2650ZWCIC @EJPCEiC @AboyansV @SilCastelletti @PTBuketAkinci @PeroneFrancesco @SMosteoru @TimKambic
5
74
2
200
11,936
Gian Manuel Jmz Rdz retweeted
Cannulas are direct/indispensable interface between patients & #ECMO but may also cause severe side-effects, as thrombosis and hemolysis! Simulation study evaluating impact of drainage cannulas design 🩸 current design reveals no-flow/stagnation areas, which may induce thrombosis, especially if EBF <2LPM 🩸 largest proportion of flow drains through proximal row of holes = risk area for hemostasis distal ⚙️ new geometric design improved pressure loss, but at the expense of pronounced distal no-flow zones ⚙️ geometry of side holes has an important impact: distal growth of hole area results improved flow @ICMexperimental 🔓 rdcu.be/jMXLG1avSyoa
11
32
1,933
Gian Manuel Jmz Rdz retweeted
🚨🚨NEW TRIAL DESIGN NOW ONLINE Should revascularisation decisions consider both ischaemia and plaque vulnerability? The COMBINE-INTERVENE Trial tests an integrated FFR- and OCT-guided PCI strategy in patients with multivessel disease. eurointervention.pcronline.c… @WWojakowski @DavidErlinge @troleder @KedhiElvin @szymonczak @DrRajeshVijay @DrTejasPatel1 @Elie__Akl @RaulmorenoMD @sbrugaletta @Eric_Van_Belle @BURZOTTA_F #PCI #OCT #FFR
1
30
4
61
7,335
Gian Manuel Jmz Rdz retweeted
🫀 VESALIUS-CV: Why Does This Trial Matter? Most PCSK9 inhibitor outcomes data has come from secondary prevention: patients who already had an MI, stroke, or major cardiovascular event. VESALIUS-CV asked a different question: can we prevent that first event? More than 12,000 high-risk patients with atherosclerosis or high-risk diabetes, but no prior MI or stroke, were randomized to evolocumab or placebo. Over a median 4.6 years: 📊 12,257 patients enrolled 📊 No prior MI or stroke 📉 25% relative risk reduction in CHD death, MI, or ischemic stroke (3-point MACE) 📉 19% relative risk reduction in the broader 4-component CV endpoint (4-point MACE) This shifts the paradigm: we now have randomized outcomes evidence supporting intensive LDL-C lowering with evolocumab before a first major cardiovascular event in appropriately selected high-risk patients. Prevent the first MI or stroke, not just the next one. 🎥 Watch the full breakdown in our latest reel. Featuring Anurag Mehta, MD, FASPC, Asst. Professor of Medicine, Cardiology, Emory University @amehta_09 Supported by an educational grant from @Amgen. ASPC maintains full editorial oversight and approval of program content. Learn more here: aspconline.org/pcsk9-educati… #VESALIUSCV #PCSK9 #PreventiveCardiology #CardiovascularHealth #LDLC #CVPrevention #MedEd #Evolocumab
2
11
2
26
3,469
Gian Manuel Jmz Rdz retweeted
LAAO in 2026: Translating New Evidence into Practice xitter.cf/i/broadcasts/1qxoNYRjM…
8
14
1,327
👀Here’s an example of why you NEVER want to use a hydrophilic wire through a needle. ⚠️High risk of sheering off the hydrophilic coating in the vessel/tissue 🔗fixed core/nitinol based wire should mainly be used for access. In micropuncture I prefer the 0.018 Nitex #Cardiology #Irad #cardioX #peripheral
5
28
3
146
31,137